G.SHDSLbis line link equipment
Line equipment
Includes RMS-4 line repeater and repeater’s containers NRP-G (soil) and NRP-N (hinged).
Repeaters are provided in leak-proof housings and can be installed into any of NRP-G (N) containers, into NRP-S1-4 container when substituting IKM-30S-4 line link equipment or into URS s of analog transmission systems with the help of optional metal frame available.
Repeaters are fed via phantom circuits of cable’s working pairs with direct current of 100 mA.
Up to eight RMS-4 repeaters can be installed from each side of remote power supply.
In the event of line breakage, after repeated switching remote power supply on, automatic loop circuit of current return triggers on in the repeater after which the breakage took place.
Temperature and humidity sensors are built-in into the repeaters what allows to get any time the information about micro climate inside the housing of any repeater via network monitoring system.
Operating ambient temperature for the repeaters is from minus 40 to plus 50°Ñ.
[Open/Save exploitation manual]
[Open/Save operator’s manual]
RMS-4 repeater |
NRP-G container |
|
|
|