G.SHDSL.bis line link equipment
Station equipment
Includes LT line modems, DP-09 remote power supply boards (substitute for DP-01 board) and secondary power supplies IP-03, IP-11 (substitute for IP-04 board).
Can be installed into MLT30/60-3U line link equipment cassette (up to 5 line kinks with remote power supply) or into M30AE flexible multiplexer cassette (one line link with remote power supply) for installation into 19” “euro” cabinet.
Available is the option of construction as 1U high unit for installation into 19” “euro” cabinet with specification at consumer’s order which allows installation of any two of station modems LT02, LT-01 (one of them may have remote power supply) or one cross-connect board (KM-08… KM-10).
Power supply from station battery 48 or 60 V.
Functions of line link station boards
LT-02 board |
Receiving/transmitting of 4 E1 streams and/or Ethernet 100Base-TÕ packets over two cable pairs |
LT-04 board |
Receiving/transmitting of 4 E1 streams over two cable pairs |
DP-09 board |
Source of remote power supply of line equipment, Irps=100 mA, Urps up to 600 V |
IP-03, IP-11 boards |
Sources of power supply from station battery (36…72 V)
|
Ordering information for MLT-30/60-1U unit:
«D11» - with remote power supply board
«L2, L4» - with one or two LT-02, LT-04 modems
«K8… K10» - with cross-connect board KM-08... KM-10
Example: MLT-30/60-1U D1-L2-K10 unit will have remote power supply board, LT-02 modem and cross-connect board KM-10.
Functions of cross-connect boards
KM-08 board |
Two programmable modes of cross-connecting 64 kb/s channels within four E1 streams or within two E1 streams and two IKM-15 streams |
KM-09 board |
Two programmable modes of cross-connecting 64 kb/s channels within four E1 streams or within two E1 streams and two IKM-15 streams, reception and forming one data transmission channel with Ethernet 100Base-TX interface |
KM-10 board |
Two programmable modes of cross-connecting 64 kb/s channels within four E1 streams or within two E1 streams and two IKM-15 streams, reception and forming two data transmission channels with Ethernet 100Base-TX interfaces |
[Open/Save exploitation manual (MLT-30/60-1U)]
[Open/Save exploitation manual (MLT-30/60-3U)]
[Open/Save operator’s manual]
LT-02 modem |
MLT-30/60-3U unit |
|
|
MLT-30/60-1U Unit |
|
|