M30AE flexible multiplexor (“euro” construction 3U)

Composition


System board

GS-01 board

      • Designed for processing and forming of E1 stream in accordance with G.703, G.704, G.706 ITU-Ò. It provides multiplexing and extracting 64 kb/s channels from E1 stream.

[Open/Save exploitation manual]


Junction lines boards


SV-01 board

      • Designed for organizing four/six-wires junction lines of rural PBXs and provides two/four-wires voice channel, two signaling wires and automatic four-wires transit.

      • Signalization from the side of analog PBX – inductive code, Nork code (Tables 7.11, 7.12 OGSTFS).

      • Signalization from the side of digital PBX – 2 dedicated signaling channels (Tables 7.18, 7.19, 7.20 OGSTFS).

      • The board contains two channels.

[Open/Save exploitation manual]

SA-01 board

      • Designed for organizing three/four-wires outgoing connection of analog PBX with battery signalization on junction, custom junction and distant dialing junction lines.

      • Signalization from the side of digital PBX – 2 dedicated signaling channels (Tables 7.18, 7.19 OGSTFS).

      • The board contains two channels.

[Open/Save exploitation manual]

SC-01 board

      • Designed for organizing three/four-wires incoming connection of analog PBX with battery signalization on junction and custom junction lines.

      • Signalization from the side of digital PBX – 2 dedicated signaling channels (Table 7.18 OGSTFS).

      • The board contains two channels.

[Open/Save exploitation manual]

SC-02 board

      • Designed for organizing three/four-wires incoming connection of analog PBX with battery signalization on distant dialing junction lines.

      • Signalization from the side of digital PBX – 2 dedicated signaling channels (Table 7.19 OGSTFS).

      • The board contains two channels.

[Open/Save exploitation manual]

SCh-01 board

      • Designed for organizing junction lines of in-zone and distant dialing lines PBXs and provides conversion of single-frequency signaling code of line signals at 2600 Hz (Tables 7.7, 7.9, 71.0 OGSTFS).

      • Signalization of digital PBX – 2 dedicated signaling channels (Tables 7.18, 7.19 OGSTFS).

      • The board contains two four-wires channels.

[Open/Save exploitation manual]

SCh-03 board

      • Designed for conversion of single-frequency signaling code at 2100 Hz into signalization of digital PBX of 1 dedicated signaling channel type (Tables 7.18, 7.19 OGSTFS).

      • The board contains two four-wires channels.

[Open/Save exploitation manual]


Subscriber boards


AR-01 board

      • Designed for connecting two telephone sets with inductor call (of TA-57 type).

[Open/Save exploitation manual]

AK-02 board

      • Direct subscribers board, contains 4 channels with FXS terminations.

[Open/Save exploitation manual]

AK-03 board

      • Direct subscribers board, contains 2 channels with FXS terminations.

[Open/Save exploitation manual]

AS-02 board

      • Direct subscribers board, station side, contains 2 channels with FXO terminations.

[Open/Save exploitation manual]>

AS-03 board

      • Direct subscribers board, station side, contains 4 channels with FXO terminations.

[Open/Save exploitation manual]


Boards for organizing data transmission channels


VE-01 board

      • Provides connection of remote local Ethernet 100 Base-TÕ networks over one (at 64 kb/s rate) or two (at 128 kb/s) of E1 channels.

      • System of two boards provides translation of the packets between two networks at 64 or 128 kb/s rate, filtration of translated packets in accordance with the addresses of the networks connected, half-duplex (UTP) or duplex (UTP-FDX) operation.

[Open/Save exploitation manual]

DS-01 board

      • The board supports one of the following interfaces: V.35, RS-232, RS-530. It occupies two channel slots.

[Open/Save exploitation manual]

DS-02 board

      • The board supports RS-232 interface. At the rates up to 57,6 kb/s it occupies one channel slot, at the rate of 115,2 kb/s it occupies two channel slots.

DS-04 board

      • The board supports RS-485 interface. At the rates up to 57,6 kb/s it occupies one channel slot, at the rate of 115,2 kb/s it occupies two channel slots.

[Open/Save exploitation manual]


Cross connection boards


KM-08 board

      • The board has two programmable modes of cross-connecting 64 kb/s channels: within 4 E1 streams or within two E1 streams and two IKM-15 streams.

[Open/Save exploitation manual, operator’s manual]

KM-09 board

      • The board has two programmable modes of cross-connecting 64 kb/s channels: within 4 E1 streams or within two E1 streams and two IKM-15 streams, receiving and forming of one data transmission channel with Ethernet 100Base-ÒÕ interface.

[Open/Save exploitation manual, operator’s manual]

KM-10 board

      • The board has two programmable modes of cross-connecting 64 kb/s channels: within 4 E1 streams or within two E1 streams and two IKM-15 streams, receiving and forming of two data transmission channels with Ethernet 100Base-ÒÕ interface.

[Open/Save exploitation manual, operator’s manual]


Line link over copper cables boards


LT-02 board

      • Receiving/transmitting of 4 E1 streams and/or Ethernet 100Base-TÕ packets in single cable operation over one or two symmetrical cable pairs at 11,2 Mb/s rate over each pair.

[Open/Save exploitation manual, operator’s manual]

LT-02-01 board

      • Similar to LT-02 board. Operates over two cables.

[Open/Save exploitation manual, operator’s manual]

LT-04 board

      • Receiving/transmitting of 4 E1 streams in single cable operation over one or two symmetrical cable pairs at 11,2 Mb/s rate over each pair.

[Open/Save exploitation manual, operator’s manual]

LT-04-01 board

      • Similar to LT-04 board. Operates over two cables.

[Open/Save exploitation manual, operator’s manual]

LT-06 board

      • Receiving/transmitting of E1 streams and/or Ethernet 100Base-TÕ packets over two pairs of co-ax cable at 11,2 Mb/s rate over each pair.

[Open/Save exploitation manual, operator’s manual]


Fiber optical line link boards


OT-01 board

      • Receiving/transmitting of E1 streams and Ethernet 100Base-TÕ packets over single-mode fiber optical cable.

[Open/Save exploitation manual]

[Open/Save operator’s manual]

OT-02 board

      • Receiving/transmitting of two E1 streams over single-mode fiber optical cable.

[Open/Save exploitation manual]

[Open/Save operator’s manual]


Radio link boards


RT-01 board

      • Interface for connecting “Neiva RD” radio station.

[Open/Save exploitation manual]

RT-02 board

      • Interface for connecting “Motorola” radio station.

[Open/Save exploitation manual]


Power supply boards


IP-11 board (substitutes IP-04 board)

      • Secondary power supply from station battery (36…72 V). Connection to network equipment monitoring system via Ethernet 100Base-TÕ interface.

[Open/Save exploitation manual]

IP-03 board

      • Secondary power supply from station battery (36…72 V). Local equipment monitoring via RS-232 interface. Advisable for use at the objects without requirement of connecting to network monitoring system.

[Open/Save exploitation manual]

DP-03 board

      • Source of remote power supply for remote M30AE multiplexor over two cable pairs; supply voltage 250 V, load current up to 0,8 A (operates jointly with SN-01 board).

[Open/Save exploitation manual]

SN-01 board

      • Conversion of remote power supply voltage, coming over two cable pairs from DP-03 board or of mains 220 VAC voltage into DC voltage – 60 V for remote subscriber equipment supply.

[Open/Save exploitation manual]

DP-04 board

      • Source of remote power supply for remote M30AE multiplexor supply over one cable pair; supply voltage 250 V, load current up to 0,8 A (operates jointly with SN-02 board).

[Open/Save exploitation manual]

SN-02 board

      • Conversion of remote power supply voltage, coming over one cable pair from DP-04 board or of mains 220 VAC voltage into DC voltage – 60 V for remote subscriber equipment supply.

[Open/Save exploitation manual]

SN-04 board

      • Conversion of stabilized remote power supply current, coming over two cable pairs from DP-07, DP-09 boards into DC voltage – 60 V for remote multiplexor supply. Complete with batteries for providing operation in peak subscribers load hours.

[Open/Save exploitation manual ]

SN-05 board

      • Conversion of 24 V voltage from UPS into 48 V for M30AE unit supply.

[Open/Save exploitation manual ]


Sources of remote power supply of the repeaters


DP-07 board (substitutes DP-06 board)

      • Remote power supply of RMS-42, RMS-44 line repeaters, Irms=200 mA, Urms up to 600 V.

[Open/Save exploitation manual (ÄÏ-07) ]

[Open/Save exploitation manual (ÄÏ-06) ]

DP-09 board (substitutes DP-01 board)

      • Remote power supply of RMS-4 line repeaters, Irms=100 mA, Urms up to 600 V.

[Open/Save exploitation manual (ÄÏ-01) ]


Technology objects parameters monitoring board


      • The board is a base device of the set of the equipment for technology objects parameters monitoring, designed for measurement of electrical parameters, climatic parameters, guard signalization function, transmitting of electric energy meters measurements having RS-485 interface, transmission of information about the state of fire signalization loops from fire alarm control and indicating equipment with relay outputs. For widening the functionalities and increasing the amount of monitoring and control points, additional devices from the set can be connecter to dedicated inputs or via RS-485 interface of KP-01 board.

[Open/Save exploitation manual]

[Open/Save operator’s manual]


Board for transmission E1 streams over the networks with packet commutation


PK-03 board

      • The board is designed for the transmission of four E1 streams over the networks with packet commutation (Ethernet, IP, MPLS). Two boards constitute transparent channel for TDM traffic between the equipment with E1 interfaces, organized in accordance with G.703/G.704/G.823.

[Open/Save exploitation manual]

[Open/Save operator’s manual]


Ethernet traffic commutation board


Ethernet traffic commutation board

      • The board is 9-ports controlled switch and is designed for commutation of local networks Ethernet traffic. The board has 8 10/100BASE-ÒÕ ports and one Gigabit Ethernet 1000BASE-Ò port.

[Open/Save exploitation manual]

[Open/Save operator’s manual]


Constructions


M30AE cassette

      • 3U, 19” construction for installing channel terminations boards, station modems and remote power supply boards when creating line links.

3U cabinet

      • Hinged construction for placing remote multiplexor.


ââåðõ